HomeProuductsSpecial Cables

Shielded, High flexible PUR single conductor

 

Application

additionally optimal compliance with electromagnetic compatibility (EMC) requirements on account of the approx. 85% coverage by the braided shielding.

Cable Construction

Construction as per TOPFLEX 301, but additionally;

Fleece wrapping between shield and jacket ;

Tinned copper braided shielding, approx. 85% coverage;

Jacket color black .


Temperature range: flexing -15°C to +80°C

Nominal voltage: acc. to VDE U0/U 600/1000 V; acc. to UL 1000 V

A.C. test voltage: 3000 V

Minimum bending radius: approx. 7,5 cable Ø

Coupling resistance: max. 250 Ohm/km


Properties 

PVC self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1

Chemical resistance see table Technical Information

 

Shielded, High flexible PUR single conductor,shielded

Conductors x cross-sec.mm² Outer Diameter Copper weight kg/km Weight ca. kg/km AWG
 Black 1x6 7.8 95.0 144.0 10
Black 1x10 9.5 124.0 170.0 8
Black 1x16 10.8 186.0 220.0 6
Black 1x25 12.2 278.0 340.0 4
Black 1x35 13.7 384.0 460.0 2
Black 1x50 15.4 530.0 580.0 1
Black 1x70 17.6 753.0 820.0 2/0
Black 1x95 21.7 1006.0 1200.0 3/0
Black 1x120 22.4 1257.0 1350.0 4/0
Black 1x150 24.3 1562.0 1680.0 300 kcmil
Black 1x185 26.5 1895.0 2100.0 350 kcmil
Black 1x240 30.3 2704.0 3100.0 500 kcmil