600/1000V XLPE Insulated, LSZH Sheathed Power Cables to BS 8573(Single Core)
FTX300 1RZ1-R (CU/XLPE/LSZH 600/1000V Class 2)


Applications
BS 8573 600/1000V XLPE Insulated, LSZH Sheathed Power Cables are generally used for fixed installation. Suitable for
building wiring, especially in areas where smoke and fume emissions may cause a potential threat to life but not for burial in the ground, either directly or in ducts.
Standard
Basic design to BS 8573:2012
FIRE PERFORMANCE
| Flame Retardance (Single vertical wire or cable test) |
IEC 60332-1-2; EN 60332-1-2 |
| Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) |
IEC 60332-3-24; EN 60332-3-24 |
| Halogen Free |
IEC 60754-1; EN 50267-2-1 |
| No Corrosive Gas Emission |
IEC 60754-2; EN 50267-2-2 |
| Minimum Smoke Emission |
IEC 61034-2; EN 61034-2 |
Voltage Rating
600/1000V
Construction
| Conductor |
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) IEC 60332-3-24; EN 60332-3-24 |
| Insulation |
XLPE type GP8 according to BS 7655-1.3. HEPR type GP6 according to BS 7655-1.2 or
crosslinked polyolefin material type EI 5 according to BS EN 50363-5 can be offered as option. |
| Inner Covering Option: |
The optional inner covering, where used, shall consist of an extruded layer of
synthetic polymeric material. It shall surround the single core and the laid-up two, three, four or five cores,
giving the assembly a practically circular shape. |
| Outer Sheath: |
Extruded layer of polymeric material LTS 4 according to BS 7655-6.1. |
| Outer Sheath Option |
UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option. |
Colour Code
| Insulation Colour |
Brown or blue. |
| Sheath Colour |
Black; other colours can be offered upon request. |
PHYSICAL AND THERMAL PROPERTIES
| Maximum temperature range during operation: |
90°C |
| Maximum short circuit temperature (5 Seconds): |
250°C |
| Minimum bending radius: |
circular copper conductors OD≤25mm : 4 × Overall Diameter
circular copper conductors OD﹥25mm: 6 × Overall Diameter
shaped copper conductors: 8 × Overall Diameter |
CONSTRUCTION PARAMETERS
| Conductor |
FTX300 1RZ1-R |
| No. of Cores × Cross- sectional Area |
Conductor Class |
Nominal Insulation Thickness |
Nominal Inner Covering
Thickness |
Nominal Sheath Thickness |
Approx. Overall Diameter |
Approx. Weight |
| No.×mm2 |
|
mm |
mm |
mm |
mm |
kg/km |
| 1×1.5 |
2 |
0.7 |
0.4 |
1.4 |
5.8 |
54 |
| 1×2.5 |
2 |
0.7 |
0.4 |
1.4 |
6.2 |
67 |
| 1×4 |
2 |
0.7 |
0.4 |
1.4 |
6.8 |
87 |
| 1×6 |
2 |
0.7 |
0.4 |
1.4 |
7.3 |
113 |
| 1×10 |
2 |
0.7 |
0.4 |
1.4 |
8.3 |
163 |
| 1×16 |
2 |
0.7 |
0.4 |
1.4 |
9.3 |
232 |
| 1×25 |
2 |
0.9 |
0.4 |
1.4 |
11.0 |
346 |
| 1×35 |
2 |
0.9 |
0.4 |
1.4 |
12.2 |
456 |
| 1×50 |
2 |
1.0 |
0.6 |
1.4 |
13.7 |
599 |
| 1×70 |
2 |
1.1 |
0.6 |
1.4 |
15.7 |
835 |
| 1×95 |
2 |
1.1 |
0.6 |
1.5 |
17.8 |
1131 |
| 1×120 |
2 |
1.2 |
0.8 |
1.5 |
19.6 |
1407 |
| 1×150 |
2 |
1.4 |
0.8 |
1.6 |
21.8 |
1727 |
| 1×185 |
2 |
1.6 |
0.8 |
1.6 |
24.0 |
2144 |
| 1×240 |
2 |
1.7 |
1.0 |
1.7 |
27.1 |
2786 |
| 1×300 |
2 |
1.8 |
1.0 |
1.8 |
29.9 |
3466 |
| 1×400 |
2 |
2.0 |
1.2 |
1.9 |
33.5 |
4405 |
| 1×500 |
2 |
2.2 |
1.2 |
2.0 |
37.2 |
5520 |
| 1×630 |
2 |
2.4 |
1.4 |
2.2 |
42.0 |
7097 |
| 1×800 |
2 |
2.6 |
1.6 |
2.3 |
46.9 |
9010 |
| 1×1000 |
2 |
2.8 |
1.6 |
2.4 |
52.0 |
11286 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information.
Electrical Properties
| Conductor Operating Temperature |
90°C |
| Ambient Temperature |
30°C |
Current-Carrying Capacities (Amp) according to BS 7671:2008 table 4E1A
| Conductor cross- sectional area |
Ref. Method
A (enclosed in
conduit in thermally
insulating wall etc) |
Ref. Method
B (enclosed in
conduit on a wall
or in trunking etc) |
Ref. Method C
(clipped direct) |
Ref. Method F (in free air or
on a perforated cable tray,
horizontal or vertical etc)
Touching |
Ref. Method G (in free
air)
Spaced by one cable
diameter |
| 2
cables,
singlephase
a.c. or
d.c. |
3 or 4
cables,
three
-phase
a.c. |
2
cables,
singlephase
a.c. or
d.c |
3 or 4
cables,
threephase
a.c. |
2 cables,
singlephase
a.c.
or d.c.
flat and
touching |
3 or 4
cables,
three-phase
a.c. flat and
touching or
trefoil |
2 cables,
singlephase
a.c. or
d.c. flat |
3
cables,
threephase
a.c. flat |
3
cables,
threephase
a.c.
trefoil |
2 cables, single-phase
a.c. or d.c. or 3 cables
three-phase a.c. flat |
| Horizontal |
Vertical |
| 1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
| mm2 |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
A |
| 1.5 |
19 |
17 |
23 |
20 |
25 |
23 |
- |
- |
- |
- |
- |
| 2.5 |
26 |
23 |
31 |
28 |
34 |
31 |
- |
- |
- |
- |
- |
| 4 |
35 |
31 |
42 |
37 |
46 |
41 |
- |
- |
- |
- |
- |
| 6 |
45 |
40 |
54 |
48 |
59 |
54 |
- |
- |
- |
- |
- |
| 10 |
61 |
54 |
75 |
66 |
81 |
74 |
- |
- |
- |
- |
- |
| 16 |
81 |
73 |
100 |
88 |
109 |
99 |
- |
- |
- |
- |
- |
| 25 |
106 |
95 |
133 |
117 |
143 |
130 |
161 |
141 |
135 |
182 |
161 |
| 35 |
131 |
117 |
164 |
144 |
176 |
161 |
200 |
176 |
169 |
226 |
201 |
| 50 |
158 |
141 |
198 |
175 |
228 |
209 |
242 |
216 |
207 |
275 |
246 |
| 70 |
200 |
179 |
253 |
222 |
293 |
268 |
310 |
279 |
268 |
353 |
318 |
| 95 |
241 |
216 |
306 |
269 |
355 |
326 |
377 |
342 |
328 |
430 |
389 |
| 120 |
278 |
249 |
354 |
312 |
413 |
379 |
437 |
400 |
383 |
500 |
454 |
| 150 |
318 |
285 |
393 |
342 |
476 |
436 |
504 |
464 |
444 |
577 |
527 |
| 185 |
362 |
324 |
449 |
384 |
545 |
500 |
575 |
533 |
510 |
661 |
605 |
| 240 |
424 |
380 |
528 |
450 |
644 |
590 |
679 |
634 |
607 |
781 |
719 |
| 300 |
486 |
435 |
603 |
514 |
743 |
681 |
783 |
736 |
703 |
902 |
833 |
| 400 |
- |
- |
683 |
584 |
868 |
793 |
940 |
868 |
823 |
1085 |
1008 |
| 500 |
- |
- |
783 |
666 |
990 |
904 |
1083 |
998 |
946 |
1253 |
1169 |
| 630 |
- |
- |
900 |
764 |
1130 |
1033 |
1254 |
1151 |
1088 |
1454 |
1362 |
| 800 |
- |
- |
- |
- |
1288 |
1179 |
1358 |
1275 |
1214 |
1581 |
1485 |
| 1000 |
- |
- |
- |
- |
1443 |
1323 |
1520 |
1436 |
1349 |
1775 |
1671 |
Voltage Drop (Per Amp Per Meter) according to BS 7671:2008 table 4E1B
| Conductor cross- sectional area |
2
cables
d.c. |
2 cables, single-phase a.c. |
3 or 4 cables, three-phase a.c. |
| Ref. Methods
A&B
(enclosed in
conduit or
trunking) |
Ref. Methods C, F&G (clipped
direct, on trays or in free air) |
Ref. Methods
A&B (enclosed
in conduit or
trunking) |
Ref. Methods C, F&G
(clipped direct, on trays or in free air) |
| Cables touching,
Trefoil |
Cables touching,
Flat |
Cables spaced*, Flat |
| Cables touching |
Cables
spaced* |
| 1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
| mm2 |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
mV/A/m |
| 1.5 |
31 |
31 |
31 |
31 |
27 |
27 |
27 |
27 |
| 2.5 |
19 |
19 |
19 |
19 |
16 |
16 |
16 |
16 |
| 4 |
12 |
12 |
12 |
12 |
10 |
10 |
10 |
10 |
| 6 |
7.9 |
7.9 |
7.9 |
7.9 |
6.8 |
6.8 |
6.8 |
6.8 |
| 10 |
4.7 |
4.7 |
4.7 |
4.7 |
4.0 |
4.0 |
4.0 |
4.0 |
| 16 |
2.9 |
2.9 |
2.9 |
2.9 |
2.5 |
2.5 |
2.5 |
2.5 |
| |
|
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
r |
x |
z |
| 25 |
1.85 |
1.85 |
0.31 |
1.90 |
1.85 |
0.190 |
1.85 |
1.85 |
0.28 |
1.85 |
1.60 |
0.27 |
1.65 |
1.60 |
0.165 |
1.60 |
1.60 |
0.190 |
1.60 |
1.60 |
0.27 |
1.65 |
| 35 |
1.35 |
1.35 |
0.29 |
1.35 |
1.35 |
0.180 |
1.35 |
1.35 |
0.27 |
1.35 |
1.15 |
0.25 |
1.15 |
1.15 |
0.155 |
1.15 |
1.15 |
0.180 |
1.15 |
1.15 |
0.26 |
1.20 |
| 50 |
0.99 |
1.00 |
0.29 |
1.05 |
0.99 |
0.180 |
1.00 |
0.99 |
0.27 |
1.00 |
0.87 |
0.25 |
0.90 |
0.86 |
0.155 |
0.87 |
0.86 |
0.180 |
0.87 |
0.86 |
0.26 |
0.89 |
| 70 |
0.68 |
0.70 |
0.28 |
0.75 |
0.68 |
0.175 |
0.71 |
0.68 |
0.26 |
0.73 |
0.60 |
0.24 |
0.65 |
0.59 |
0.150 |
0.61 |
0.59 |
0.175 |
0.62 |
0.59 |
0.25 |
0.65 |
| 95 |
0.49 |
0.51 |
0.27 |
0.58 |
0.49 |
0.170 |
0.52 |
0.49 |
0.26 |
0.56 |
0.44 |
0.23 |
0.50 |
0.43 |
0.145 |
0.45 |
0.43 |
0.170 |
0.46 |
0.43 |
0.25 |
0.49 |
| 120 |
0.39 |
0.41 |
0.26 |
0.48 |
0.39 |
0.165 |
0.43 |
0.39 |
0.25 |
0.47 |
0.35 |
0.23 |
0.42 |
0.34 |
0.140 |
0.37 |
0.34 |
0.165 |
0.38 |
0.34 |
0.24 |
0.42 |
| 150 |
0.32 |
0.33 |
0.26 |
0.43 |
0.32 |
0.165 |
0.36 |
0.32 |
0.25 |
0.41 |
0.29 |
0.23 |
0.37 |
0.28 |
0.140 |
0.31 |
0.28 |
0.165 |
0.32 |
0.28 |
0.24 |
0.37 |
| 185 |
0.25 |
0.27 |
0.26 |
0.37 |
0.26 |
0.165 |
0.30 |
0.25 |
0.25 |
0.36 |
0.23 |
0.23 |
0.32 |
0.22 |
0.140 |
0.26 |
0.22 |
0.165 |
0.28 |
0.22 |
0.24 |
0.33 |
| 240 |
0.190 |
0.21 |
0.26 |
0.33 |
0.20 |
0.160 |
0.25 |
0.195 |
0.25 |
0.31 |
0.185 |
0.22 |
0.29 |
0.170 |
0.140 |
0.22 |
0.170 |
0.165 |
0.24 |
0.170 |
0.24 |
0.29 |
| 300 |
0.155 |
0.175 |
0.25 |
0.31 |
0.160 |
0.160 |
0.22 |
0.155 |
0.25 |
0.29 |
0.150 |
0.22 |
0.27 |
0.140 |
0.140 |
0.195 |
0.135 |
0.160 |
0.21 |
0.135 |
0.24 |
0.27 |
| 400 |
0.120 |
0.140 |
0.25 |
0.29 |
0.130 |
0.155 |
0.20 |
0.125 |
0.24 |
0.27 |
0.125 |
0.22 |
0.25 |
0.110 |
0.135 |
0.175 |
0.110 |
0.160 |
0.195 |
0.110 |
0.24 |
0.26 |
| 500 |
0.093 |
0.120 |
0.25 |
0.28 |
0.105 |
0.155 |
0.185 |
0.098 |
0.24 |
0.26 |
0.100 |
0.22 |
0.24 |
0.090 |
0.135 |
0.160 |
0.088 |
0.160 |
0.180 |
0.085 |
0.24 |
0.25 |
| 630 |
0.072 |
0.100 |
0.25 |
0.27 |
0.086 |
0.155 |
0.175 |
0.078 |
0.24 |
0.25 |
0.088 |
0.21 |
0.23 |
0.074 |
0.135 |
0.150 |
0.071 |
0.160 |
0.170 |
0.068 |
0.23 |
0.24 |
| 800 |
0.056 |
- |
0.072 |
0.150 |
0.170 |
0.064 |
0.24 |
0.25 |
- |
0.062 |
0.130 |
0.145 |
0.059 |
0.155 |
0.165 |
0.055 |
0.23 |
0.24 |
| 1000 |
0.045 |
- |
0.063 |
0.150 |
0.165 |
0.054 |
0.24 |
0.24 |
- |
0.055 |
0.130 |
0.145 |
0.050 |
0.155 |
0.165 |
0.047 |
0.23 |
0.24 |
Note: *Spacings larger than one cable diameter will result in a large voltage drop.
r = conductor resistance at operating temperature
x = reactance
z = impedance