NF F 63-826 Rolling Stock Cables FRF-SW-1.5S, FRF-SW-3S

A. Conductor B. Insulation C. Sheath

Application

These cables are used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor, suitable for use in control, auxiliary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc

Construction

Conductor
Stranded tinned copper wires to IEC 60228 Class 5

Insulation
Halogen free compound

Sheath
Halogen free compound

Electrical & Mechanical Properties

Nominal Voltage 1500V, 3000V
Maximum Conductor Temperature 90°C/105°C
Minimum Permissible Ambient Temperature -25°C~90°C
Bending Radius 4 × Overall Diameter

Standards

NF F 63-826
NF F 16-101
BS 6853
EN45545-2

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
EN45545-2 Requirement for fire behavior of materials & components R15/R16

FRF-SW-1.5S 1500V

Nominal Cross Sectional Area Number & Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter Weight
Min. Max.
mm² No/mm mm mm mm mm kg/km
1.5 30/0.25 2.3 1.5 8.9 9.9 130
2.5 50/0.25 2.3 1.5 9.3 10.3 145
10.0 80/0.40 2.3 1.8 11.9 13.3 290
50.0 396/0.40 2.5 2.2 18.3 20.3 850
120.0 608/0.50 2.8 2.6 25.0 27.5 1770
150.0 756/0.50 2.8 2.6 26.7 29.3 2150
185.0 925/0.50 2.9 2.8 29.0 31.8 2530

FRF-SW-3S 3000V


Nominal Cross Sectional Area
Number & Nominal Diameter of Strands Nominal Insulation Thickness Nominal Sheath Thickness Overall Diameter Weight
Min. Max.
mm² No/mm mm mm mm mm kg/km
150.0 756/0.50 3.6 2.6 28.2 30.9 2270
185.0 925/0.50 3.7 2.8 30.5 33.4 2660