HomeProuductsFiretox LSZH Flame Retardant Instrumentation & Data Cables

LSZH Flame Retardant CAT6A GSWB Armoured CPR Data Cables

FTX-CAT6AS/FTP4P23LH GSWB

LSZH Flame Retardant CAT6A GSWB Armoured CPR Data Cables

APPLICATION

Cat6A Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. The galvanized steel wire braid armor provides excellent protection.The LSZH sheath can reduce toxic smoke and fume emission.

STANDARDS

ISO/IEC 11801、 EN 50173、 ANSI/TIA/EIA 568

FIRE PERFORMANCE

Flame Retardance (Single vertical wire or cable test) IEC 60332-1-2; EN 60332-1-2
Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) IEC 60332-3-24; EN 60332-3-24
Halogen Free IEC 60754-1; EN 50267-2-1
No Corrosive Gas Emission IEC 60754-2; EN 50267-2-2
Minimum Smoke Emission IEC 61034-2; EN 61034-2
CPR Compliance B2ca,Cca

CABLE CONSTRUCTION

Conductors : 23AWG solid bare copper.
Insulation : FPE.
Twinning : Two coloured insulated conductors twisted together to form a pair.
Inner Sheath : Thermoplastic LSZH compound, coloured black.
Armouring : Galvanized steel wire braid with 85% coverage.
Outer Sheath : Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered).
Outer Sheath Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite properties can be offered as option.

Physical AND THERMAL PROPERTIES

Temperature range : -20°C - +70°C
Minimum bending radius during installation (mobile state) : 15 × Overall Diameter
Minimum bending radius during operation (fixed state) : 8 × Overall Diameter

Electrical Properties

AWG   23
Nominal Conductor Diameter mm 0.56/0.57/0.58
Maximum DC Resistance@20°C Ω/100m 7.5
Maximum DCR Unbalance % 3
Maximum Mutual Capacitance pF/m 5.8
Maximum Capacitance Unbalance pF/100m 30
Characteristic Impedance@1-100MHz Ω 100±20
Maximum Propagation Delay Skew ns/100m 18

TRANSMISSION PROPERTIES

FREQ Attenuation NEXT PSNEXT ELFEXT PSELFEXT RL
MHz dB/100m dB dB dB/100m dB/100m dB
0.772 1.8 76.0 74.0 70.0 67.0
1 2.0 74.3 72.3 67.8 64.8 20.0
4 3.8 65.3 63.3 55.7 52.7 23.0
8 5.3 60.8 58.8 49.7 46.7 24.5
10 6.0 59.3 57.3 47.8 44.8 25.0
16 7.6 56.3 54.3 43.7 40.7 25.0
20 8.5 54.8 52.8 41.7 38.7 25.0
25 9.5 53.3 51.3 39.8 36.8 24.3
31.25 10.7 51.9 49.9 37.9 34.9 23.6
62.5 15.4 47.4 45.4 31.8 28.8 21.5
100 19.8 44.3 42.3 27.8 24.8 20.1
155 25.2 41.5 39.5 23.9 20.9 18.8
200 29.0 39.8 37.8 21.7 18.7 18.0
250 32.8 38.3 36.3 19.8 16.8 17.3

CONSTRUCTION PARAMETERS

Cable Code Conductor Diameter Aprrox. Overall Diameter Nominal Weight
  mm mm kg/km
FTX-CAT6AS/FTP4P23LH GSWB 4×2×0.57/0.58 14.0±1.5 200
Cable Code Conductor Diameter Aprrox. Overall Diameter Nominal Weight
  mm mm kg/km
FTX-CAT6AS/FTP4P23LH GSWB 4×2×0.57/0.58 14.0±1.5 200
Note : The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information.