HomeProuductsMIL-Spec Wire and Cables

M81381/18

Application and Description

These FEP/polyimide/FEP tape insulated single-core M81381/18 cables are used in aerospace applications and other challenging applications. It is well-suited to applications concerned with smoke emission and overload stability.

Construction

M81381/18 MIL-Spec Wire and Cables
Conductor Stranded nickel-plated copper conductor
Insulation FEP/polyimide/FEP tape insulation
Insulation Wall Thickness 0.0065”
Jacket modified aromatic poyimide coating

Characteristics

Temperature Range -55°C + 200°C
Voltage Rating 600 volts
Color Code MIL-STD-104 (See page 42 ) 10 basic colors(BLK,BRN,RED,ORN,YEL,GRN,BLU,VIO,GRY,WHT)

Dimensions and Weight

AWG Size Conductor Stranding Conductor Diam.?Max. Conductor Diam.?Min. Max. O.D. Min. O.D. Maximum Resistance (Ohm/1000' @ 20°C) Approx LBS/MFT
? ? in mm in mm in mm in mm ? ?
26 19/38 0.020 0.510 0.018 0.460 0.030 0.762 0.028 0.711 42.20 1.2
24 19/36 0.024 0.610 0.023 0.580 0.035 0.889 0.032 0.813 25.90 1.8
22 19/34 0.031 0.790 0.029 0.740 0.041 1.041 0.038 0.965 16.00 2.6
20 19/32 0.039 0.990 0.037 0.940 0.049 1.245 0.046 1.168 9.77 4.1
18 19/30 0.049 1.240 0.046 1.170 0.058 1.473 0.055 1.397 6.10 6.3
16 19/29 0.055 1.400 0.052 1.320 0.065 1.651 0.062 1.575 4.76 7.9
14 19/27 0.069 1.750 0.065 1.650 0.078 1.981 0.075 1.905 3.00 12.3
12 37/28 0.089 2.260 0.084 2.130 0.098 2.489 0.094 2.388 1.98 19.0