HomeProuductsMining Cable

Mining Cable
Type G Four-Conductor Portable Power Cable 2kV

Applications

These ype G Four-Conductor Portable Mining Power Cable are designed for use with mobilemining equipment, such as continuous miners, cutting or loading machines,conveyors, drills or pump

Standards

  • ICEA S-75-381/NEMA WC 58
  • ASTM B 172
  • ASTM B 33
  • CAN/CSA C22.2 No. 96

Construction

Type G Four-Conductor Portable Power Cable 2kV Mining Cable

  • Conductors: Stranded annealed tinned copper conductor.
  • Insulation:EPR.
  • Grounding Conductor:Tinned copper conductor with a green outer covering.
  • Sheath: Reinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered as an option.

Options:Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

  • Minimum Bending Radius: 6×OD
  • Maximum Operating Temperature: +90℃

Dimensions and Weight:

Construction No. of Strands Grounding Conductor Size Nominal Insulation Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil - AWG/kcmil inch mm inch mm lbs/kft kg/km A
4×6 259 12 0.06 1.5 1.10 27.9 910 1354 72
4×4 412 10 0.06 1.5 1.27 32.3 1378 2050 93
4×2 259 9 0.06 1.5 1.48 37.6 1914 2848 122
4×1 331 8 0.08 2.0 1.68 42.7 2311 3438 143
4×1/0 414 7 0.08 2.0 1.79 45.5 2810 4181 165
4×2/0 522 6 0.08 2.0 1.93 49.0 3253 4840 192
4×3/0 658 5 0.08 2.0 2.07 52.6 4099 6099 221
4×4/0 829 4 0.08 2.0 2.26 57.4 4925 7327 255
4×250 973 3 0.095 2.4 2.66 67.6 6060 9016 280
4×350 1361 1 0.095 2.4 2.98 75.7 8126 12090 335
4×500 1921 1/0 0.095 2.4 3.40 86.4 10758 16006 395

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.